Detailed content

Polyforte One-component Hardener D

Please contact (020)38744012

Appropriate for using on new carborundum floor with good hardness. Avoid using on loose, atomized concrete surface.

Manual

1.Roughly grind the surface with the grinding discs in the order of 30, 50, 100-disk.

2.And then grind the surface with 200 to 300-disk grinding discs.

3.Wash off the mortar with water. Then leave the surface to dry.

4.Apply agent D on surface, and keep moist for half an hour.

5.Polish the surface well when agent D is dry.

 

Attention

 1.Before treatment, grind the surface until ground layer is visible.

 2.The surface should be cleaned well and completely dry, so the component D could penetrate sufficiently.

 3.Polish surface on the second day after component D is applied to have a better viewing.The estimated consumption is 0.2kg/m2.